Gujarat, IndiaISO 9001:2015 · CE · One Star Export House
Cast-resin dry type transformer in an indoor electrical room (illustrative)
Transformers

Dry Type Transformer

Dry type transformers use air cooling and solid insulation (typically cast resin) instead of oil, which removes the fire and leak risk of an oil-filled unit. That makes them the preferred choice inside buildings, basements and other places close to people.

They need little maintenance and can be supplied with an enclosure, temperature monitoring and forced-air fans to suit the installation.

Key specifications

Dry Type Transformer specifications

SpecificationValue
TypeCast Resin Dry Type
RatingUp to 3.5 MVA
Voltage ClassUp to 33kV
Voltage Ratio0.400kV/0.600kV
Frequency50 Hz
Phase3 Phase
Cooling TypeONAN/ONAF
Vector GroupDyn11 or As Per Required
Winding MaterialCopper/Aluminium
Insulation ClassA
TappingOff Circuit Tap Link/Off Circuit Tap Changer Or On-Load Tap Changers for Variation As Per customer's specification
ImpedanceIn Line With Applicable Standards/ customer's specification
Applicable StandardIS, IEC, IEEE etc.

Ratings shown are typical catalogue values. Final specification is confirmed per order.

Buying guide

Dry type or oil-cooled?

Dry type transformers use cast resin or vacuum-impregnated insulation instead of oil, so there is no oil to leak or catch fire and no soak pit is needed. That makes them the usual choice for basements, high-rise buildings, hospitals, malls and indoor substations close to the load. The trade-off is a higher purchase price and a need for clean, ventilated rooms.

Specify the kVA, voltages, insulation class, enclosure protection (IP rating) and whether you need forced-air cooling for extra capacity. For outdoor yards, an oil-cooled distribution transformer is usually more economical. Dry type units are commonly fed from an RMU and feed a PCC panel.

Applications

Where it is used

  • High-rise buildings and malls
  • Hospitals and data centres
  • Indoor substations in plants
  • Metro, airport and tunnel projects
FAQ

Dry Type Transformer – FAQ

Why choose a dry type transformer?

There is no oil to leak or catch fire, so it can be installed indoors close to the load with simpler fire-protection requirements.

Do dry type transformers need an enclosure?

An IP-rated enclosure is usually specified for safety and protection against dust and touch; it can be omitted inside a locked electrical room.

Get a price

Get today's price

Tell us what you need. We reply with price, availability and delivery time.

Please include

  • Product, brand or model
  • Capacity, rating or size
  • Quantity
  • Delivery location

Send your enquiry

We reply with price, availability and delivery time.

Get a dry type transformer quote

Tell us the rating, quantity and delivery location. We reply with options, price and delivery time.